VRF Retrofit for Hotels and ALFs in South Florida

VRF Retrofit for Hotels and Assisted Living Facilities in South Florida

A lot of hotels and assisted living facilities in South Florida still cool their rooms with equipment that was installed decades ago. Old packaged terminal units in every room, aging split systems, or an air handler and chiller setup that has outlived its parts. When it is time to replace it, VRF is one of the options that keeps coming up.

VRF stands for variable refrigerant flow. One outdoor unit, or a bank of them, serves many indoor units, and each room or zone gets its own control. Here is how we think about a VRF retrofit for hotels and ALFs in Broward, Palm Beach and Miami Dade.

Each guest room or resident room can be set on its own, which fits how hotels and ALFs actually use the space.

The compressors live outside or on the roof, not in the wall under the window.

VRF ramps up and down with demand instead of cycling on and off, which suits buildings where many rooms are empty or lightly used at any given time.

Refrigerant piping is much easier to run through an existing building than new ductwork.

VRF is not right for every building. Very large buildings with a working central plant may be better served by upgrading the chillers and air handlers. Big open spaces like ballrooms and dining rooms may still want a dedicated unit. And VRF on its own does not solve fresh air.

That last point is the one we stress the most. In South Florida, bringing outside air into a building means bringing in a lot of moisture. A VRF retrofit usually needs a dedicated outdoor air system to condition and dry the ventilation air before it reaches the rooms. Skip that and you get rooms that feel cool but damp. In a hotel that means musty rooms and bad reviews. In an ALF it means comfort and health complaints from residents who cannot just open a window.

In a hotel, rooms are inventory. A VRF retrofit is usually done in blocks of floors or room stacks, so a section goes offline, gets finished and goes back on sale. Outdoor units and refrigerant risers often go in first, while guests are still in the rooms, and then each floor gets its indoor units, piping and controls in a short window.

Noise, dust and hallway traffic need a plan. So does the electrical. New outdoor units may need new feeders and disconnects, and taking out old through wall units changes the room circuits. Because we handle the HVAC and the electrical, those pieces stay in the same schedule.

An ALF is a home, and the residents depend on the cooling. Florida's rule for assisted living facilities requires an emergency power plan and the ability to keep a cooled area safe during an outage. If a VRF retrofit changes the system serving that area, or changes what the generator has to carry, the emergency power plan may need to be amended and resubmitted. Our post on

During the work, we keep enough of the building cooled at all times, schedule around meals and rest times, and keep construction out of resident spaces as much as possible.

Survey the existing system, the electrical service and the roof or grade space for outdoor units.

Size the system room by room and decide how fresh air will be handled.

Design the refrigerant piping routes, condensate drains and controls.